| Modellkennung LL | Artikel-Nr. LL | Leistungserklärung LL |
|---|---|---|
| CAQ600-L-PH-STT-GB - Zehnder ComfoAir Q600 with Pre-Heater, Left Handed | 471502025 | 1603044Q60010.pdf(47 KB) |
| Steuerung LL | Energieeffizienzklasse LL | Energieeffizienz-Label LL |
| Energy Label – Central demand control | GB-label_CAQ600_471502025_A.pdf(91 KB) | |
| Energy Label – Manual control | GB-label_CAQ600_471502025_A.pdf(91 KB) | |
| Energy Label – Local demand control | GB-label_CAQ600_471502025_A+.pdf(92 KB) | |
| Energy Label – Clock control | GB-label_CAQ600_471502025_A.pdf(91 KB) |
| Label | Value |
|---|---|
| Catalogue number | 471502025 |
| GTIN | 8717573874458 |
| Production model | COMFOAIR Q600 GB L PH ST |
| Air flow rate | 600 m³/h |
| Amperage | 10.3 A |
| Supply voltage | 230 V |
| Frequency | 50 Hz |
| Noise/Sound Level | 51 |
| Energy class I | A |
| Energy class II | A+ |
| With volatile organic compound (VOC) sensor | |
| Housing material | Steel |
| Material heat exchanger | Other |
| Housing material quality | Other |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Supporting protocol for Modbus | |
| Nominal duct diameter | 180-200 mm |
| With bypass | |
| Housing material | Steel coated |
| Type of speed control | Other |
| Max. air volume at 100 Pa | 600 m³/h |
| Suitable for wall mounting | |
| Nominal duct diameter | 180-200 mm |
| With thermal overload protection | |
| Type of motor | Electronically commutated (EC) |
| With wired control unit | |
| With internal carbon dioxide (CO2) sensor | |
| Suitable for floor mounting | |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Width | 725 mm |
| Residential connection, top | |
| Width | 725 mm |
| Type of motor | Electronically commutated (EC) |
| Power consumption at max. air volume at 100 Pa | 0.258 kW |
| Type of motor | Electronically commutated (EC) |
| Degree of protection (IP) | IP40 |
| Connections residential side | Insert-/duct end |
| Electrical connection | Connecting cable with plug with protective contact |
| Suitable for central heating boiler connection | |
| Width | 725 mm |
| Thermal efficiency at 70 % air volume at 50 Pa | 90 % |
| Frequency | 50 Hz |
| Depth | 570 mm |
| Max. air volume at 200 Pa | 600 m³/h |
| Frequency | 50 Hz |
| Roof connection, side | |
| Max. air volume at 150 Pa | 600 m³/h |
| Suitable for ceiling mounting | |
| Residential connection, left side | |
| Left/right orientation reversible | |
| Residential connection, underside | |
| Number of phases | 1 |
| Residential connection, right side | |
| Heat recovery by | Cross-counter-flow unit |
| Suitable for wireless remote control | |
| Housing material quality | Other |
| Max. air volume at 50 Pa | 420 m³/h |
| Cos phi according to EPN standard | 0.54 |
| With internal carbon dioxide (CO2) sensor | |
| With zone controller | |
| Thermal efficiency according to EPN standard | 90 % |
| With volatile organic compound (VOC) sensor | |
| Power input according to EPN standard | 0.174 kW |
| Fuse size of the device | 16 A |
| With constant volume flow control | |
| With bypass | |
| Power electric heating element | 0-1740 W |
| Suitable for wall mounting | |
| Material heat exchanger | Other |
| With thermal overload protection | |
| Voltage | 230 V |
| Suitable for floor mounting | |
| Depth | 570 mm |
| Suitable for central heating boiler connection | |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Max. air volume at 100 Pa | 600 m³/h |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Suitable for wireless remote control | |
| Roof connection, top | |
| Residential connection, left side | |
| Roof connection, side | |
| Residential connection, underside | |
| Residential connection, top | |
| Residential connection, right side | |
| With digital display | |
| Max. air volume at 150 Pa | 600 m³/h |
| Weight | 48 kg |
| Max. air volume at 200 Pa | 600 m³/h |
| Height | 850 mm |
| Depth | 570 mm |
| With digital display | |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Roof connection, top | |
| Height | 850 mm |
| Operation by app | |
| Voltage | 230 V |
| Heat recovery by | Cross-counter-flow unit |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Voltage | 230 V |
| Weight | 48 kg |
| Suitable for ceiling mounting | |
| With internal humidity (RH) sensor | |
| Left/right orientation reversible | |
| Suitable for (extra) humidity (RH) sensor | |
| Power consumption at max. air volume at 100 Pa | 0.258 kW |
| Frequency | 50 Hz |
| Energy efficiency class according to 1253/2014/EU | A+ |
| With constant pressure control | |
| Electrical connection | Connecting cord with plug with protective contact |
| With constant volume flow control | |
| Housing material | Steel |
| Type of frost protection | Heating element |
| Suitable for extra VOC sensor | |
| Connections residential side | Insert-/duct end |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Connections outdoor air side | Insert-/duct end |
| Max. air volume at 50 Pa | 420 m³/h |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Electrical connection | Connecting cord with plug with protective contact |
| Nominal duct diameter | 180-200 mm |
| Power electric heating element | 0-1740 W |
| With heating element | |
| Electrical connection | Connecting cable with plug with protective contact |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Energy efficiency class | A+ |
| With wired control unit | |
| Suitable for wired control unit | |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Supporting protocol for Modbus | |
| Suitable for (extra) humidity (RH) sensor | |
| Suitable for extra VOC sensor | |
| With internal humidity (RH) sensor | |
| Suitable for zone controller | |
| Degree of protection (IP) | IP40 |
| With heating element | |
| Fuse size of the device | 16 A |
| Connections outdoor air side | Insert-/duct end |
| Suitable for zone controller | |
| Type of frost protection | Heating element |
| With zone controller | |
| With constant pressure control | |
| Suitable for wired control unit | |
| Voltage | 230 V |
| Height | 850 mm |
| Number of phases | 1 |
| Thermal efficiency at 70 % air volume at 50 Pa | 90 % |
| Nominal duct diameter | 180-200 mm |
| Weight | 48 kg |
| Operation by app | |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Fuse size of the device | 16 A |
General Request
Contact FormOffer Request
Contact FormOrder Request
Contact FormGeneral Request
+44 (0) 1276 605 800Technical Support
+44 (0) 1276 605 800We need your consent to load this content
We use a third party service that may collect data about your activity to embed this content. Please review the details and accept the service to access it.
Consent to Data Processing
In order to use our “MyZehnder Solution Finder” service your consent to the use of the chatbot service “Zendesk Chat” and to the associated processing and storage of your inputs is required. The data you provide will be stored in a cloud infrastructure and used exclusively to process your inputs and to improve our service. Please note that without your consent the use of our “MyZehnder Solution Finder” service is not possible. Your data will be treated confidentially and will not be disclosed to unauthorized third parties. Further information on the processing of your personal data can be found in our privacy policy.