| Modellkennung LL | Artikel-Nr. LL | Leistungserklärung LL |
|---|---|---|
| CAQ350-L-PH-STT-GB - Zehnder ComfoAir Q350 with Pre-Heater, Left Handed | 471502017 | 1603044Q35010.pdf(47 KB) |
| Steuerung LL | Energieeffizienzklasse LL | Energieeffizienz-Label LL |
| Energy Label – Central demand control | EU-label_CAQ350_471502017_A+.pdf(97 KB) | |
| Energy Label – Manual control | GB-label_CAQ350_471502017_A.pdf(91 KB) | |
| Energy Label – Local demand control | EU-label_CAQ350_471502017_A+.pdf(97 KB) | |
| Energy Label – Clock control | GB-label_CAQ350_471502017_A.pdf(91 KB) |
| Label | Value |
|---|---|
| Catalogue number | 471502017 |
| GTIN | 8717573874373 |
| Production model | COMFOAIR Q350 GB L PH ST |
| Air flow rate | 350 m³/h |
| Amperage | 7.6 A |
| Supply voltage | 230 V |
| Frequency | 50 Hz |
| Noise/Sound Level | 40 |
| Energy class I | A |
| Energy class II | A+ |
| Housing material | Steel |
| Frequency | 50 Hz |
| Left/right orientation reversible | |
| Degree of protection (IP) | IP40 |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Supporting protocol for Modbus | |
| Depth | 570 mm |
| Type of speed control | Other |
| Max. air volume at 100 Pa | 350 m³/h |
| Nominal duct diameter | 160-190 mm |
| Suitable for wall mounting | |
| With thermal overload protection | |
| Nominal duct diameter | 160-190 mm |
| Height | 850 mm |
| Electrical connection | Connecting cord with plug with protective contact |
| With bypass | |
| With wired control unit | |
| Housing material | Steel coated |
| With internal carbon dioxide (CO2) sensor | |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Suitable for wired control unit | |
| Suitable for floor mounting | |
| Housing material quality | Other |
| Suitable for ceiling mounting | |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Width | 725 mm |
| Type of motor | Electronically commutated (EC) |
| Degree of protection (IP) | IP40 |
| Connections residential side | Insert-/duct end |
| Electrical connection | Connecting cable with plug with protective contact |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Suitable for (extra) humidity (RH) sensor | |
| Suitable for zone controller | |
| Suitable for central heating boiler connection | |
| Weight | 52 kg |
| Roof connection, top | |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Roof connection, side | |
| Weight | 52 kg |
| Housing material | Steel |
| Suitable for ceiling mounting | |
| Power consumption at max. air volume at 100 Pa | 0.101 kW |
| Max. air volume at 200 Pa | 350 m³/h |
| Electrical connection | Connecting cord with plug with protective contact |
| Suitable for extra VOC sensor | |
| Max. air volume at 150 Pa | 350 m³/h |
| Max. air volume at 50 Pa | 245 m³/h |
| Residential connection, left side | |
| With internal carbon dioxide (CO2) sensor | |
| Residential connection, underside | |
| With zone controller | |
| Residential connection, top | |
| With volatile organic compound (VOC) sensor | |
| Residential connection, right side | |
| Fuse size of the device | 10 A |
| Suitable for wireless remote control | |
| With constant volume flow control | |
| Power electric heating element | 0-1740 W |
| Width | 725 mm |
| Power electric heating element | 0-1740 W |
| Cos phi according to EPN standard | 0.42 |
| Voltage | 230 V |
| With digital display | |
| With heating element | |
| Depth | 570 mm |
| With wired control unit | |
| Height | 850 mm |
| Material heat exchanger | Other |
| With internal humidity (RH) sensor | |
| Thermal efficiency according to EPN standard | 94 % |
| Fuse size of the device | 10 A |
| Power input according to EPN standard | 0.086 kW |
| With zone controller | |
| Thermal efficiency at 70 % air volume at 50 Pa | 94 % |
| With bypass | |
| Efficiency supply filter according to ISO 16890-1:2016 | 55 % |
| Suitable for wall mounting | |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| With thermal overload protection | |
| Thermal efficiency at 70 % air volume at 50 Pa | 94 % |
| Suitable for floor mounting | |
| Frequency | 50 Hz |
| Suitable for central heating boiler connection | |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Max. air volume at 100 Pa | 350 m³/h |
| Operation by app | |
| Suitable for wireless remote control | |
| Heat recovery by | Cross-counter-flow unit |
| With digital display | |
| Voltage | 230 V |
| Residential connection, left side | |
| Left/right orientation reversible | |
| Residential connection, underside | |
| Material heat exchanger | Other |
| Residential connection, top | |
| Number of phases | 1 |
| Residential connection, right side | |
| Type of motor | Electronically commutated (EC) |
| Roof connection, top | |
| Heat recovery by | Cross-counter-flow unit |
| Roof connection, side | |
| With volatile organic compound (VOC) sensor | |
| Max. air volume at 150 Pa | 350 m³/h |
| Housing material quality | Other |
| Max. air volume at 200 Pa | 350 m³/h |
| Power consumption at max. air volume at 100 Pa | 0.101 kW |
| Width | 725 mm |
| Max. air volume at 50 Pa | 245 m³/h |
| Nominal duct diameter | 160-190 mm |
| Type of motor | Electronically commutated (EC) |
| Height | 850 mm |
| Electrical connection | Connecting cable with plug with protective contact |
| Depth | 570 mm |
| Energy efficiency class | A+ |
| Supply filter according to ISO 16890-1:2016 | ISO ePM1 |
| Suitable for wired control unit | |
| Voltage | 230 V |
| Supporting protocol for Modbus | |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Suitable for extra VOC sensor | |
| Weight | 52 kg |
| Suitable for zone controller | |
| With internal humidity (RH) sensor | |
| With heating element | |
| Suitable for (extra) humidity (RH) sensor | |
| Connections outdoor air side | Insert-/duct end |
| Frequency | 50 Hz |
| Type of frost protection | Heating element |
| With constant pressure control | |
| With constant pressure control | |
| With constant volume flow control | |
| Voltage | 230 V |
| Type of frost protection | Heating element |
| Number of phases | 1 |
| Connections residential side | Insert-/duct end |
| Nominal duct diameter | 160-190 mm |
| Connections outdoor air side | Insert-/duct end |
| Operation by app | |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Fuse size of the device | 10 A |
General Request
Contact FormOffer Request
Contact FormOrder Request
Contact FormGeneral Request
+44 (0) 1276 605 800Technical Support
+44 (0) 1276 605 800We need your consent to load this content
We use a third party service that may collect data about your activity to embed this content. Please review the details and accept the service to access it.
Consent to Data Processing
In order to use our “MyZehnder Solution Finder” service your consent to the use of the chatbot service “Zendesk Chat” and to the associated processing and storage of your inputs is required. The data you provide will be stored in a cloud infrastructure and used exclusively to process your inputs and to improve our service. Please note that without your consent the use of our “MyZehnder Solution Finder” service is not possible. Your data will be treated confidentially and will not be disclosed to unauthorized third parties. Further information on the processing of your personal data can be found in our privacy policy.