| Modellkennung LL | Artikel-Nr. LL | Leistungserklärung LL |
|---|---|---|
| CA350-BS-L-SD-GB-MC5 - Zehnder ComfoAir 350, Left Handed | 471233400 | 1511044350000.pdf(48 KB) |
| Steuerung LL | Energieeffizienzklasse LL | Energieeffizienz-Label LL |
| Energy Label – Central demand control | GB-label_CA350_471233400_A.pdf(91 KB) | |
| Energy Label – Manual control | GB-label_CA350_471233400_A.pdf(91 KB) | |
| Energy Label – Local demand control | GB-EU-label_CA350_471233400_A+.pdf(142 KB) | |
| Energy Label – Clock control | GB-label_CA350_471233400_A.pdf(91 KB) |
| Label | Value |
|---|---|
| Catalogue number | 471233400 |
| GTIN | 5030216110267 |
| Production model | COMFOAIR 350 GB L |
| Air flow rate | 400 m³/h |
| Amperage | 1.77 A |
| Supply voltage | 230 V |
| Frequency | 50 Hz |
| Noise/Sound Level | 55 |
| Energy class I | A |
| Energy class II | A+ |
| Electrical connection | Cable |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Max. air volume at 300 Pa | 300 m³/h |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| With wired control unit | |
| Voltage | 230 V |
| Type of speed control | Other |
| Degree of protection (IP) | IP44 |
| Nominal duct diameter | 150-160 mm |
| Suitable for wall mounting | |
| With thermal overload protection | |
| Nominal duct diameter | 150-160 mm |
| Height | 864 mm |
| Suitable for ceiling mounting | |
| Max. air volume at 100 Pa | 409 m³/h |
| Power consumption at max. air volume at 100 Pa | 0.243 kW |
| With bypass | |
| Voltage | 230 V |
| Housing material | Steel coated |
| With zone controller | |
| Electrical connection | Cable |
| With heating element | |
| Suitable for floor mounting | |
| Power consumption at max. air volume at 100 Pa | 0.243 kW |
| With internal humidity (RH) sensor | |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Housing material | Plastic |
| Width | 710 mm |
| With zone controller | |
| With constant volume flow control | |
| Electrical connection | Cable |
| With internal humidity (RH) sensor | |
| Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
| Left/right orientation reversible | |
| With internal carbon dioxide (CO2) sensor | |
| Suitable for central heating boiler connection | |
| Number of phases | 1 |
| Roof connection, top | |
| Thermal efficiency at 70 % air volume at 50 Pa | 90 % |
| Roof connection, side | |
| Housing material | Steel |
| Energy efficiency class according to 1253/2014/EU | A+ |
| With volatile organic compound (VOC) sensor | |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Max. air volume at 250 Pa | 342 m³/h |
| Weight | 31.58 kg |
| Max. air volume at 200 Pa | 364 m³/h |
| Housing material quality | Expanded polypropylene (EPP) |
| Number of phases | 1 |
| Max. air volume at 150 Pa | 387 m³/h |
| Suitable for extra VOC sensor | |
| Residential connection, left side | |
| Electrical connection | Cable |
| Residential connection, underside | |
| With wired control unit | |
| Residential connection, top | |
| With heating element | |
| Residential connection, right side | |
| Connections residential side | Insert-/duct end |
| Suitable for wireless remote control | |
| With internal carbon dioxide (CO2) sensor | |
| Depth | 268 mm |
| Width | 710 mm |
| Suitable for (extra) humidity (RH) sensor | |
| Cos phi according to EPN standard | 0.53 |
| Suitable for zone controller | |
| With digital display | |
| Suitable for wired control unit | |
| Depth | 585 mm |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Height | 850 mm |
| Suitable for ceiling mounting | |
| Type of motor | Electronically commutated (EC) |
| Thermal efficiency according to EPN standard | 96.4 % |
| Max. air volume at 50 Pa | 350 m³/h |
| Power input according to EPN standard | 0.0384 kW |
| Energy efficiency class | A+ |
| Supporting protocol for Modbus | |
| With bypass | |
| Voltage | 230 V |
| Suitable for wall mounting | |
| Degree of protection (IP) | IP44 |
| With thermal overload protection | |
| Weight | 39 kg |
| Suitable for floor mounting | |
| Frequency | 50 Hz |
| Suitable for central heating boiler connection | |
| Heat recovery by | Cross-counter-flow unit |
| Max. air volume at 100 Pa | 409 m³/h |
| Material heat exchanger | Plastic |
| Suitable for wireless remote control | |
| Housing material quality | Expanded polypropylene (EPP) |
| With digital display | |
| Type of motor | Electronically commutated (EC) |
| Residential connection, left side | |
| Suitable for extra VOC sensor | |
| Residential connection, underside | |
| Suitable for (extra) humidity (RH) sensor | |
| Residential connection, top | |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Residential connection, right side | |
| Material heat exchanger | Plastic |
| Roof connection, top | |
| Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
| Roof connection, side | |
| Thermal efficiency at 70 % air volume at 50 Pa | 90 % |
| Max. air volume at 150 Pa | 387 m³/h |
| Frequency | 50 Hz |
| Max. air volume at 250 Pa | 342 m³/h |
| Left/right orientation reversible | |
| Max. air volume at 200 Pa | 364 m³/h |
| Heat recovery by | Cross-counter-flow unit |
| Width | 710 mm |
| With volatile organic compound (VOC) sensor | |
| Nominal duct diameter | 150-160 mm |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Height | 850 mm |
| Max. air volume at 50 Pa | 350 m³/h |
| Depth | 585 mm |
| Type of motor | Electronically commutated (EC) |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Suitable for wired control unit | |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Supporting protocol for Modbus | |
| Weight | 31.58 kg |
| Suitable for zone controller | |
| Frequency | 50 Hz |
| Connections outdoor air side | Insert-/duct end |
| With constant pressure control | |
| Type of frost protection | Other |
| With constant volume flow control | |
| With constant pressure control | |
| Type of frost protection | Other |
| Max. air volume at 300 Pa | 300 m³/h |
| Connections residential side | Insert-/duct end |
| Nominal duct diameter | 150-160 mm |
| Connections outdoor air side | Insert-/duct end |
| Voltage | 230 V |
General Request
Contact FormOffer Request
Contact FormOrder Request
Contact FormGeneral Request
+44 (0) 1276 605 800Technical Support
+44 (0) 1276 605 800We need your consent to load this content
We use a third party service that may collect data about your activity to embed this content. Please review the details and accept the service to access it.
Consent to Data Processing
In order to use our “MyZehnder Solution Finder” service your consent to the use of the chatbot service “Zendesk Chat” and to the associated processing and storage of your inputs is required. The data you provide will be stored in a cloud infrastructure and used exclusively to process your inputs and to improve our service. Please note that without your consent the use of our “MyZehnder Solution Finder” service is not possible. Your data will be treated confidentially and will not be disclosed to unauthorized third parties. Further information on the processing of your personal data can be found in our privacy policy.