| Modellkennung LL | Artikel-Nr. LL | Leistungserklärung LL |
|---|---|---|
| CA160-BS-SD-GB-MCF - Zehnder ComfoAir 160 | 471219625 | 2103044160000.pdf(391 KB) |
| Steuerung LL | Energieeffizienzklasse LL | Energieeffizienz-Label LL |
| Energy Label – Central demand control | EU-label_CA160_471219630_A.pdf(95 KB) | |
| Energy Label – Manual control | EU-label_CA160_471219630_A.pdf(95 KB) | |
| Energy Label – Local demand control | GB-EU-label_CA160_471219625_A+.pdf(142 KB) | |
| Energy Label – Clock control | EU-label_CA160_471219630_A.pdf(95 KB) |
| Label | Value |
|---|---|
| Catalogue number | 471219625 |
| GTIN | 8717573036764 |
| Production model | COMFOAIR 160 GB |
| Air flow rate | 165 m³/h |
| Supply voltage | 230 V |
| Frequency | 50 Hz |
| Noise/Sound Level | 41 |
| Energy class I | A |
| Energy class II | A+ |
| Left/right orientation reversible | |
| With volatile organic compound (VOC) sensor | |
| Weight | 29.58 kg |
| Residential connection, right side | |
| Nominal duct diameter | 125-155 mm |
| Depth | 268 mm |
| Type of frost protection | Other |
| Max. air volume at 50 Pa | 169 m³/h |
| With wired control unit | |
| With internal carbon dioxide (CO2) sensor | |
| Height | 864 mm |
| Housing material quality | Other |
| With digital display | |
| Housing material | Steel |
| Nominal duct diameter | 125-155 mm |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Type of motor | Electronically commutated (EC) |
| Suitable for zone controller | |
| Voltage | 230 V |
| Voltage | 230 V |
| Operation by app | |
| Suitable for ceiling mounting | |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Left/right orientation reversible | |
| Weight | 29.58 kg |
| Depth | 268 mm |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Supply filter according to ISO 16890-1:2016 | ISO Coarse |
| Width | 670 mm |
| Height | 864 mm |
| Suitable for wireless remote control | |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Residential connection, underside | |
| Weight | 29.58 kg |
| Roof connection, side | |
| With thermal overload protection | |
| Suitable for ceiling mounting | |
| Type of motor | Electronically commutated (EC) |
| Power consumption at max. air volume at 100 Pa | 0.067 kW |
| Electrical connection | Connecting cord with plug with protective contact |
| Heat recovery by | Cross-counter-flow unit |
| Nominal duct diameter | 125-155 mm |
| With thermal overload protection | |
| Suitable for wall mounting | |
| Max. air volume at 50 Pa | 169 m³/h |
| Frequency | 50 Hz |
| Type of motor | Electronically commutated (EC) |
| Type of speed control | Other |
| With zone controller | |
| Max. air volume at 100 Pa | 168 m³/h |
| With volatile organic compound (VOC) sensor | |
| With constant pressure control | |
| Connections outdoor air side | Duct end |
| With constant volume flow control | |
| Max. air volume at 100 Pa | 168 m³/h |
| Type of frost protection | Other |
| Max. air volume at 300 Pa | 97 m³/h |
| Connections residential side | Duct end |
| Nominal duct diameter | 125-155 mm |
| Connections outdoor air side | Duct end |
| With bypass | |
| Exhaust filter according to ISO 16890-1:2016 | ISO Coarse |
| Housing material | Steel coated |
| Material heat exchanger | Other |
| With heating element | |
| Thermal efficiency at 70 % air volume at 50 Pa | 95 % |
| With wired control unit | |
| Suitable for floor mounting | |
| Suitable for (extra) humidity (RH) sensor | |
| Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
| With internal humidity (RH) sensor | |
| Thermal efficiency at 70 % air volume at 50 Pa | 91 % |
| Suitable for zone controller | |
| Frequency | 50 Hz |
| With zone controller | |
| Depth | 268 mm |
| Suitable for wired control unit | |
| Height | 864 mm |
| Suitable for floor mounting | |
| Frequency | 50 Hz |
| Efficiency supply filter according to ISO 16890-1:2016 | 65 % |
| Residential connection, left side | |
| Width | 670 mm |
| Residential connection, top | |
| Suitable for (extra) carbon dioxide (CO2) sensor | |
| Roof connection, top | |
| Suitable for central heating boiler connection | |
| Operation by app | |
| Roof connection, top | |
| Heat recovery by | Cross-counter-flow unit |
| Roof connection, side | |
| Width | 670 mm |
| Max. air volume at 250 Pa | 128 m³/h |
| Material heat exchanger | Other |
| With internal carbon dioxide (CO2) sensor | |
| Number of phases | 1 |
| Max. air volume at 200 Pa | 155 m³/h |
| Energy efficiency class according to 1253/2014/EU | A+ |
| Max. air volume at 150 Pa | 166 m³/h |
| Housing material | Steel |
| Energy efficiency class | A+ |
| Suitable for extra VOC sensor | |
| Residential connection, left side | |
| Housing material quality | Other |
| Residential connection, underside | |
| Power consumption at max. air volume at 100 Pa | 0.067 kW |
| Residential connection, top | |
| Suitable for central heating boiler connection | |
| Residential connection, right side | |
| Electrical connection | Connecting cord with plug with protective contact |
| Suitable for wireless remote control | |
| Electrical connection | Connecting cable with plug with protective contact |
| Cos phi according to EPN standard | 0.56 |
| Max. air volume at 300 Pa | 97 m³/h |
| With digital display | |
| Suitable for wired control unit | |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Supporting protocol for Modbus | |
| Thermal efficiency according to EPN standard | 95 % |
| Suitable for extra VOC sensor | |
| Supporting protocol for Modbus | |
| With heating element | |
| Power input according to EPN standard | 0.067 kW |
| With constant volume flow control | |
| Number of phases | 1 |
| Connections residential side | Duct end |
| Voltage | 230 V |
| With constant pressure control | |
| With bypass | |
| Max. air volume at 150 Pa | 166 m³/h |
| With internal humidity (RH) sensor | |
| Max. air volume at 250 Pa | 128 m³/h |
| Suitable for (extra) humidity (RH) sensor | |
| Max. air volume at 200 Pa | 155 m³/h |
| Suitable for wall mounting | |
| Electrical connection | Connecting cable with plug with protective contact |
| Efficiency exhaust filter according to ISO 16890-1:2016 | 65 % |
| Voltage | 230 V |
General Request
Contact FormOffer Request
Contact FormOrder Request
Contact FormGeneral Request
+44 (0) 1276 605 800Technical Support
+44 (0) 1276 605 800We need your consent to load this content
We use a third party service that may collect data about your activity to embed this content. Please review the details and accept the service to access it.
Consent to Data Processing
In order to use our “MyZehnder Solution Finder” service your consent to the use of the chatbot service “Zendesk Chat” and to the associated processing and storage of your inputs is required. The data you provide will be stored in a cloud infrastructure and used exclusively to process your inputs and to improve our service. Please note that without your consent the use of our “MyZehnder Solution Finder” service is not possible. Your data will be treated confidentially and will not be disclosed to unauthorized third parties. Further information on the processing of your personal data can be found in our privacy policy.